Re: Nested Datawindow Report (Datawindow Printing)Does anyone know if this problem has been corrected in PB 8
or 9? Please advise. I am currently using PB 7.
Problem: In case of large text fields, PowerBuilder not
printing the Data correctly. Lines are cut in half and also
not printing last few lines . This is happening on nested
datawindow.
Here is the link to the original documentation:
http://info.sybase.com/resolution/detail.stm?id_number=10938800
Original documentation :-) states that this is not a bug but expected
behaviour, so what kind of "correction" do you expect?
pbm_thisusuallydoesnothelp:-))
Philip ...
Re: Composite Datawindow Report (Cut off on printing)I have one main datawindow which has 10 datawindows. One of
the datawindows has a field which has more than 10,000
characters. When I go to preview my main datawindow, on
page 4 of 10 the text filed which has more than 10,000
characters is being cut off at the top of the page(The text
field is on a deatil band). Half of the text remains on 3rd
page and half on 4th page. The header and footer print
properly. Can anyone tell me if this is a Powerbuiler 7 bug
or not? Any help would be greately appreciated.
Please post your messages in only one news group.
thanks
John
Team Sybas...
Printing a datawindow with a nested datawindow under Win95Hi PB'ers
We have a strange problem when trying to print a datawindow with a
nested datawindow.
Printing from a 32 bit (interpreted or compiled) application under
windows 95, the application crashes in the Kernel32.dll.
If the same application is run under NT3.51 the there are no problems.
The same goes if the same application is made as a 16 bit application.
(running under NT, Win3 or Win95).
We have the same problem in more than one application with different
datawindows being printed, but the application doesn't crash every time
a datawindow with a nested datawindo...
How to share the datawindow to inner datawindow of nested datawindowHow to share the datawindow to inner datawindow of nested datawindow.
Ex
--------
dw_1 is normal datawindow dw_nes is nested datawindow, both are placed
one window
dw_nes contain dw_child datawindow
Question
----------------
i want to share dw_1 and dw_child.
I have tried the below code, getting error
dw_1.sharedata( dw_nes.object.dw_child)
It's the dot notation. You will need to dw_nes.GetChild("dw_child", ldwc)
where ldwc is a _local_ datawindowchild.
<kzganesan@gmail.com> wrote in message
news:4c64c402-bac5-4ee0-83aa-4ac08ffe43e5@r66g2000hsg.go...
Reference a datawindow object (nested report) in a datawindowIs it possible to reference a datawindow object in a datawindow?
My scenario :
I have a datawindow (composite) which holds another datawindow (nested
report).
This child datawindow has a OLE ActiveX object which I am trying to access
from the window which holds the composite datawindow.
The reason for this is because I need to access the ActiveX
properties/functions after the composite datawindow have been retrieved.
I've tried to get a reference to the child datawindow :
//DataWindowChild dwc_activex
dw1.getchild("dw_activex", dwc_activex)
But as datawi...
Nested datawindow within a nested datawindowI have a report, that contains a datawindow, which itself contains a
datawindow. Everything is working fine until the number of retrieved lines
get's over about 1100 primary and over about 3200 retrieved nested lines.
Although the task manager (I'm using Powerbuilder 7.0.3 on Windows 2000)
shows me, that there is still enough free memory, the data retrieval stops
and Powerbuilder (or the application which called the Retrieve() method)
ends itself without any error message. That allways happens when the
datawindow has allocated about 70 MB of virtual memory. (About 99% of those
...
DataWindow This, DataWindow That...Blah blah blah
You've heard it enough that you don't even want to comment on how many
times...
The DataWindow.
....but it can't be enough anymore...can it?
This from one of our colleagues
(and yes my apologies for taking it out of context)...
"...PB covers all you need to do that in ONE Tool. This
includes Windowprogramming ( meaning the interface to the user:
Windows, Sheets, diallougeboxes, etc.), Database operability AND
Reporting! Well, I see als well as many other PB users that some of
the implementations and features PB offers are improvable. But thi...
nested datawindow within another nested datawindow?I was trying to create a report which has a nested datawindow within another
nested datawindow, and PB didn't seem to go for this... got memory errors.
Is this even possible? I searched all of the usual resources and couldn't
find anything about this... maybe they assumed nobody would be dumb enough
to try.
thanks,
Pat
It is perfectly legal to have multiple levels of nested reports. However,
nesting isn't supported for certain DW types like grid and n-up. Try testing
your DWs on their own to ensure that they work properly. Then nest them one
at a time and try to i...
No nested datawindows or n-up datawindows?Hi:
Are there no nested datawindows or n-up datawindows in Pocket?
I can't seem to add them in the painter, yet the help describes the
properties rows_Per_detail...
Regards
Currently, these DW types are not supported in PK 2.0.2.
"Ignacio Mateos" <imateos@telefonica.net> wrote in message
news:43282d5f$1@forums-2-dub...
> Hi:
>
> Are there no nested datawindows or n-up datawindows in Pocket?
>
> I can't seem to add them in the painter, yet the help describes the
> properties rows_Per_detail...
>
> Regards
>
...
Child datawindows (Nested DataWindows)Hello all...I was wondering... I have used Child Datawindows
for quite some time under PB9.03. These are invaluable when
a user is in the Parent DataWindow and must choose a value
from a list of choices provided by the Child DataWindow. The
kind of Child DataWindow I am talking about is a
DropDownDataWindow (DDDW). This is the only kind I have ever
used. I was simply wondering whether there are more kinds of
Child DataWindows other than the DDDW? Any info would be
greatly appreciated.:)
The next most popular use is of child DWs within
Composite Presentation Style parents.
Nested ...
omit the print preview in a datawindow where a nested report is insideHi,
is it possible to omit the print preview in a datawindow where a nested
report is inside? That means i want to display the datawindow in the normal
mode on the screen and not having a page break and the blue line around the
datawindow.
Thanx in advance for any idea!
Dietmar
Dietmar Fuchs wrote:
> Hi,
>
> is it possible to omit the print preview in a datawindow where a nested
> report is inside? That means i want to display the datawindow in the normal
> mode on the screen and not having a page break and the blue line around the
> datawindow....
I will print two datawindow in one page,and I use child datawindow.One master datawindow (dw_master)with two child datawindow(dc1 and dc2)dw_master("dw_dc1",dc1)
dw_master("dw_dc2",dc2)
dc1 has a argument (arg1)
dc2 has a argument (arg2)
Arg1 and Arg2 are send by one column of dw_master.
When I use retrieve() function,the datawindow can display normal,but when I
print preview or use Zoom or printsetup() ,the childdatawindow dc2 can't
display but dc1 normal!
Why??
Thanks for your help!
I'm having trouble understanding your question. Is this a composite or nested
datawindow?
On Mon, 6 May 2002 22:49:23 +0800,
in powersoft.public.powerbuilder.datawindow
spark <fenfei79@hot...
Problem PB 9.0 printing datawindows with nested reports?Hi all,
I tried to migrate my application from PB 8.0.3 to PB 9.0 (5077 with the
patch from 27-03-2003) but to my great disappointment, I am immediately
confronted with a problem. While printing a composite report which has
nested reports which also contain nested reports, these last nested reports
don't get printed, this however works fine in PB 8.0.3 and strange enough
retrieving the main datawindow in the development environment also works
fine in 9.0. but apparently using this datawindow in a datastore though a
window-object doesn't work anymore, anybody knows a workaroun...
Printing composite DW resets datawindow.zoom on nested reportsHi, I have a problem with composite DW. In composite DW I have nested
report, named for example dw_data. I set zoom on dw_data for example to 200:
datawindowchild dwchild
dw_1.GetChild('dw_data',dwchild)
dwchild.Modify('datawindow.zoom=200')
It's all OK. But when I then print DW by using
dw_1.print()
then zoom of dwchild is automaticly set back to 100.
Is this a PB bug or I am doing something wrong?
R Kazimir
rkazimir@centrum.cz
...