Effect on Sybase: HP UX 10.20

We are trying to implement the C2 security (converting to a trusted system)
on the HP UX 10.20. We are currently running SYBASE 11 on the box.

My question is:
Does Sybase gets effected in any way when converting to a trusted system?
Has anybody converted to a trusted system when a database is running?
Is it safe to do it?

I would appreciate it if anybody could give me some feedback on this.

Thanks in advance.

Chandra Shekhar


0
Chandra
9/11/1997 1:29:08 PM
sybase.sqlserver.unix 1493 articles. 0 followers. Follow

0 Replies
499 Views

Similar Articles

[PageSpeed] 42

Reply:

Similar Artilces:

Smoking 9063 for HP-UX 11.00, HP-UX 10.20, AIX 4.3 *and* AIX 4.2
Not bad at all ... Smoking patch 9063 OK: for both stdio and perlio ok: skipped (would be OK) --: unable to build (e.g. no 64 bit machine) ##: fail HP-UX HP-UX AIX AIX 11.00 10.20 4.3 4.2 OK OK OK OK -Uuseperlio OK OK OK OK -Duseperlio OK -- OK -- -Duseperlio -Duse64bitint OK -- -- -- -Duseperlio -Duse64bitall ok ok OK ## -Duseperlio -Duselongdouble ok -- ## -- -Duseperlio -Dusemorebits ok -- -- -- -Duseperlio -Duse64bitall -Duselongdouble OK OK OK ## -Uuseperlio -Dusethreads -Duseithreads O...

HP-UX 10.20
Somewhere between 30348 (all 'O' report) and 30372 ('M' and 'm'): Processing hints file hints/hpux.pl Note (probably harmless): No library found for -lucb Note (probably harmless): No library found for -lposix Note (probably harmless): No library found for -lcposix Can't locate auto/POSIX/autosplit.ix in @INC (@INC contains: ../../lib ../../lib /pro/lib/perl5/5.9.5/PA-RISC2.0 /pro/lib/perl5/5.9.5 /pro/lib/perl5/site_perl/5 ..9.5/PA-RISC2.0 /pro/lib/perl5/site_perl/5.9.5 .) at ../../lib/AutoLoader.pm lin e 186. at POSIX.pm line 9 Making header files f...

HP-UX 10.20
I'll dig, but pointers welcome ... 30871 Configuration (common) -Dcc=gcc ----------- --------------------------------------------------------- O O O O O O O O O O O O -Duseithreads 30900 Configuration (common) none ----------- --------------------------------------------------------- O O O O O O ? - - - - - -Duseithreads <-- Hangs 31132 Configuration (common) none ----------- --------------------------------------------------------- c - - c - - c - - c - - -Duseithreads 31132 Configuration (common) -Dcc=gcc ----------- -------------...

HP-UX 10.20 blead
Smoke killed, manual build threaded debugging. What can I do to get more info? A full build+test takes about 4=C2=BD hours :( so binary searching will take weeks. Test Summary Report ------------------- re/reg_fold.t (Wstat: 0 T= ests: 4722 Failed: 0) TODO passed: 458, 2632, 4398, 4404, 4410, 4416, 4422 4428, 4434 re/regexp_qr_embed_thr.t (Wstat: 0 T= ests: 1398 Failed: 958) Failed tests: 323-338, 342-352, 356, 358-361, 364-367 369-378, 380-440, 442-4...

HP-UX 10.20 and threading
Enabling threading on HP-UX 10.20 again (Whew, am I glad I wrote those docs :)) the only warning I got was during Configure: : What pager is used on your system? [/pro/bin/less] pid_t found. Checking how to generate random libraries on your machine... cc: "try.c", line 47: error 1529: Cannot select field of non-structure. cc: "try.c", line 47: error 1549: Modifiable lvalue required for assignment operator. cc: "try.c", line 50: warning 604: Pointers are not assignment-compatible. cc: "try.c", line 50: warning 563: Argument #2 is not the correc...

9057 @ HP-UX 10.20
Smoking patch 9057 Configuration: -Dusedevel -Uuseperlio ------------------------------------------------------------------------------ PERLIO = stdio u=3.02 s=0.72 cu=166.64 cs=21.43 scripts=301 tests=21723 All tests successful. PERLIO = perlio u=2.94 s=0.65 cu=170.58 cs=21.55 scripts=301 tests=21723 All tests successful. Configuration: -Dusedevel -Duseperlio ------------------------------------------------------------------------------ PERLIO = stdio u=3.24 s=0.74 cu=176.46 cs=21.79 scripts=302 tests=21748 All tests successful. PERLIO = perlio u=...

Threading on HP-UX 10.20
Nick: is the d_casti32 hint still appropriate, or has it become obsolete over time. If so, should I test without, and if so, in what configuration to show it's failure/success best. Arthur: I've now forced the newest available libcma.sl to be used instead o= f the original version that is still hanging out there to make Oracle= 7 happy. Anyone: Those try.c errors should either be silenced or solved. d3:/pro/local/lib 112 > ll *cma* 16218 -r-xr-xr-x 1 merijn softwr 528384 Feb 26 13:44 libcma-23672.= 1 20861 lrwxrwxrwx 1 m...

HP-UX 10.20 status
cc -DDEBUGGING +DAportable -Ae -D_HPUX_SOURCE -I/pro/local/include \ -D_LARGEFILE_SOURCE -D_FILE_OFFSET_BITS=64 -I./include \ -o platform.o -c platform.c cpp: "platform.c", line 6: error 4036: Can't open include file 'dlfcn.h'. make: *** [platform.o] Error 1 -- H.Merijn Brand Amsterdam Perl Mongers (http://amsterdam.pm.org/) using perl-5.6.1, 5.7.2 & 630 on HP-UX 10.20 & 11.00, AIX 4.2, AIX 4.3, WinNT 4, Win2K pro & WinCE 2.11. Smoking perl CORE: smokers@perl.org http://archives.develooper.com/daily-build@perl.org/ perl-qa@perl.org ...

HP-UX 10.20 wants to participate
OK, I do *not* like this, but at least it makes 10.20 happy: Enable hinting d_u32align. Since I'm not very happy with this workaround, I have not done much about the format (indent), but at least Configure can now skip the hang part if it has been hinted to. Messages are not restored to the outside level, so /if/ it has been hinted, you don't see /how/ it was hinted. I'm still awaiting some reply from HP, and otherwise, I'll compose a bug report. I've got no hopes however that HP is going to get out another patch for 10.20. At least with these two I get t/op/pat...

Threads broken on HP-UX 10.20
http://doc.procura.nl/smoke/hpux1020/511/cc/mktest.rpt v5.11.2-160-g421f30e Configuration (common) none ----------- --------------------------------------------------------- F F F F F F F F ? - - - -Duseithreads | | | | | +- LC_ALL = univ.utf8 -DDEBUGGING | | | | +--- PERLIO = perlio -DDEBUGGING | | | +----- PERLIO = stdio -DDEBUGGING | | +------- LC_ALL = univ.utf8 | +--------- PERLIO = perlio +----------- PERLIO = stdio http://doc.procura.nl/smoke/hpux1020/511/gcc/mktest.rpt v5.11.2-160-g421f30e Configuration (common) -Dcc=gcc ----------- -----------------------------...

Patches for ASE12 on HP-UX 10.20
Hi all, I'm looking at upgrading a machine from Sybase 11.0.3.3 to 12.0 on a HP-UX 10.20. Looking at the Sybooks/ Sybase site, I see a number of patches are required for HP-UX if using version 11.x. However, are there any required patches if using 10.20? Or does it assume that if upgrading from 11.9.x, all required patches will have been installed? So, should I review the release notes for 11.5.x, 11.9.x and ensure that those patches installed? thanks Paul Morris Hi Paul, As it turns out, this is a moot point. I'm sorry to say that the Release Bulletin/Instal...

HP-UX 10.20 and ASE 12
Is anyone running this 'combination' and if so, have you seen any problems? John Langston This is a multi-part message in MIME format. --------------B6D292B9F444A56227539C20 Content-Type: text/plain; charset=us-ascii Content-Transfer-Encoding: 7bit John Langston wrote: > Is anyone running this 'combination' and if so, have you seen any problems? > > John Langston Hi John, You need HPUX 11 for ASE 12. j --------------B6D292B9F444A56227539C20 Content-Type: text/x-vcard; charset=us-ascii; name="jfroebe.vcf" Content-Transfer-...

XP Server on HP-UX 10.20
I tried to call xp_cmdshell from within a ASE 11.5.1 Server on HP-UX. But XP server can't be started by ASE. When I start XP Server manually all works fine. After (every) startup ASE reports error 7215 to the errorlog file. I proved all the checks proposed in ASE Release Bulletin, but I can't find out why XP Server won't start after the first call of an xp. I installed another ASE 11.5.1 on Solaris and XP Server starts immediatly when calling e.g. xp_cmdshell. On Solaris there is no error 7215 after ASE startup. Any ideas??? TIA Karl Jost ...

ODBC Driver for UNIXPLATFORM HP-UX 10.20
Hello, I need an ODBC driver for the OS HP-UX 10.20 ( Unixplatform ) Where I can download this driver, and what I am doing to install this driver? Thanks a lot Hasan �g�r -- GMX - Die Kommunikationsplattform im Internet. http://www.gmx.net ...

Thread fail/hang on HP-UX 10.20
Not that I ever shipped a threaded perl build, let alone on HP-UX 10.20, but I noticed that the last smoke that actually passed the threaded test on my 10.20 was 30871. The next report was for 30900, which was a hang. That situation has not changed since. Change 30900 on 2007/04/10 by nicholas@nicholas-saigo 'Silence the g++ warnings "right' Change 30899 on 2007/04/10 by nicholas@nicholas-saigo '$ExtUtils::MM_Unix::VERSION is ' Change 30898 on 2007/04/10 by nicholas@nicholas-saigo 'Cast needed to get POSIX compil' Change 30897 on 2007/04/10 by nicholas@n...