powerbuilder 10 build 8075 datawindow dddw bug.

If the datawindow column type is money and has dddw, I get error message 
"Expression is invalid".
If I replace dot with comma in regional settings, I can solve the problem.
I am using Turkish Charset.

thanks 


0
Murat
9/2/2005 9:06:55 AM
sybase.powerbuilder.general 62418 articles. 17 followers. Follow

1 Replies
540 Views

Similar Articles

[PageSpeed] 39

We also get the same error message when we apply a filter that has a dash
'-' in the expression (using setFilter()). We went back to 8050.

Larry

"Murat Yelkovan" <muratyelkovan@yahoo.com> wrote in message
news:43181629$1@forums-2-dub...
> If the datawindow column type is money and has dddw, I get error message
> "Expression is invalid".
> If I replace dot with comma in regional settings, I can solve the problem.
> I am using Turkish Charset.
>
> thanks
>
>


0
Larry
9/2/2005 12:33:56 PM
Reply:

Similar Artilces:

PowerBuilder 10.5.2 Build 7826 differs from PowerBuilder 11.5.1 Build 4675
Apparently there's some data conversion issues that differ from PowerBuilder 10.5.2 and 11.5.1 (builds listed in subject). The following mini scrip results in different returned values: Byte lb_test Decimal ld_test lb_test = 48 ld_test = Dec(lb_test) MessageBox("Test", String(ld_test)) In PowerBuilder 10.5.2, the messagebox displays the value "48". In PowerBuilder 11.5.1 the messagebox displays the value "0.48". It appears that in PB 11.5.1, it's dividing the result by 100 for some reason. It appears to be a bug, just wanted to ve...

update powerbuilder 10.0 to powerbuilder 10.5
hi, I need update powerbuilder ver 10.0 to powerbuilder 10.5. by the way, my company already buy pb ver 10.00 and need to update to ver 10.5. the question : if update pb from ver 10.00 to ver 10.5, is it free of charge ? if no, How I found the price ? best regards, alim 10.5 is considered a major release, you would need to purchase an upgrade. This is what I found on Sybase's own eshop: http://eshop.sybase.com/eshop/buy_detail?id=92023&prodId=9281&bid=17856 You may find better through an online merchant, partner or local retailer. This is also the Ent...

Powerbuilder 5 to Powerbuilder 10
Hi all We have migrated our application from powerbuilder 5 to powerbuilder 10. after migration to version 10, alignment in most of reports disturbed. please advice me some solution. On Fri, 29 Feb 2008 12:45:01 +0100, Adnan Jamil <adnanjamil@nji.com.pk> wrote: > Hi all > > We have migrated our application from powerbuilder 5 to powerbuilder 10. > after migration to version 10, alignment in most of reports disturbed. > please advice me some solution. Adnan, Is this a SQL Anywhere question? If not, you have posted to the wrong forum. If yes,...

Emergency Bug Fixer in PowerBuilder 10.2 build 8035
HI all, What are the Emergency Bug Fixers(EBFs) in Power Builder after version 10.2 Build 8035. Are these EBFs available for free download in Sybase site. Regards Udayanath Well, there's a full MR (10.2.1) after that EBF. There's also 10.2.0 EBF builds 8050, 8075, 8100. The MR is build 9004, and then there's several EBFs beyond that, through about build 9823. They're all available in the Downloads -> EBF/Maintenance section of the Sybase web site. You have to set the timeframe back to "in all months" to see many of them though. On 11...

Powerbuilder 9.0.1 Build 7204 Datawindow Bug
After installing the latest patch, any of our dynamic datawindows containing a timestamp have the timestamp field overlapping other columns. I'm not sure if it is the timestamp property itself or the specific column, but no changes were made to the database and this error occurred as soon as the 7204 patch was applied. This is a serious error. Do anybody know similar problem occuring in PB9 or earlier version? Any solution, is it a reported bug? Thanks in Advance VSV John, What was the prior build that you used? Reason is we are using 9.0.1.7151 and moving to 9.01.7204 t...

powerbuilder 10 build 8075 window maximize icon problem!!!
Hi all There are no maximize and minimize buttons on the title bar, if I open windows as maximized. What OS are you running? Are you seeing the min/max icons when the window is not maximized? On 1 Sep 2005 06:18:23 -0700, in sybase.public.powerbuilder.general Murat Yelkovan <muratyelkovan@yahoo.com> wrote: >Hi all >There are no maximize and minimize buttons on the title bar, if I open >windows as maximized. > > OS version is XP service pack 1 Powerbuilder 10.2 8075 I am opening window with opensheet. Windowtype of w_test is main and windows...

PowerBuilder 7.0.3 Build 10108 Datawindow Update Properties Bug
When setting the Update Properties for a DataWindow Object, columns of datatype 'datetime' are not listed under the 'Unique Key Columns' listbox. We are connecting to a Microsoft SQL Server 7.0 database using a MSS 6.x driver. Anyone experience this problem? Our only workaround is to export the object to text, modify it manually, and then re-import the object. We're concerned that this is too dangerous and could possibly corrupt the object. Also, does anyone know where/how to obtain a native mode SQL 7.0 driver for PB 7? Thanks, Check the documentation...

Rich text based datawindow print problem with powerbuilder 10.5 build 5063
I have upgraded our powerbuilder 8 application to 10.5 build 5063. When I view the rich text base datawindows, they look fine in the display. But, as soon as I click print, the column values turn to ?? on the screen and also prints ?? for columns. Any body knows how to resolve printing issue in powerbuilder 10.5 build 5063? ...

Upgrade to PowerBuilder 9 or PowerBuilder 10?
Hi, Our company is going to upgrade PowerBuilder. Currently we are using version 7, and we are going to upgrade either to version 9 or 10. Does anyone have any recommendations if we should go for version 9 or 10? What is the current release of version 10, and is it stable or is there a lot of bugs? Best regards, Ronald Ommundsen e-mail: ronald.ommundsen@gard.no Ron; If you have any hope of running the applications in the future on XP, W2003 or soon to be W2006 (LongHorn) you will have to jump over to UniCode - ie PB10. So personally, I would recommend starting with P...

PowerBuilder Datawindow Bug
Folks, I just wanted to follow up with the work-arround I did on a PowerBuilder 8.0.3.9704 and SQL Server 2000 (latest patch) bug. The bug lies in the MSS database driver. Basically PowerBuilder truncates any string comprosed entirely of spaces to the empty string as it retrieves from the database to the datawindow. The solution for me was to wrap any candidate column with this scenario with a non-blank string (I used the string '##'), and then after datawindow retrieve, loop through datawindow, and remove the string from each side of the queried columns. Tons of overh...

Announcing the PowerBuilder 10 Public Beta Program!Join the PowerBuilder 10.0 Beta Team!
Join the PowerBuilder 10.0 Beta Team! PowerBuilder is getting ready for the 10.0 release and would like to invite you to join the Beta Team! The exciting new developments you will have early access to as a member of the Beta Team include: Unicode support DataWindow.NET Object Oriented Modeling with PowerDesigner plug-in UDDI search ADO.NET support NETXML Web Datawindow Your participation in the beta test cycle is an opportunity to provide valuable feedback to engineering regarding the quality and capabilities of this release. As a member of the team, you will learn from the e...

Moving from PowerBuilder 6.5 to PowerBuilder 10
Hi, I have an application developed in PB6.5 and due to changing requirements application has to be switched to PB10. There when I am trying to regenerate the contents of my PBL, it is giving error stating: C0042 : cannot compile without valid database signon. This error is coming for few windows but not for the functions I have made in my pbl. It is working perfectly fine for pb6.5. Can you please help me on this. Thanks in advance. Manich First you must to connect to the database by a profile, continue migrate your app. Karla <Manich Tripathi> escribi...

PowerBuilder 9.0 and PowerBuilder 10.0
Hello NG ,,, I have a strange problem , installed both versions of PowerBuilder on the same machine having Windows XP. under Program files\Sybase9 - > PB9.0 was installed . under Program files\Sybase10- > PB10.0 was installed, I was working on XML workspace in PB9.0 where in the library list PBDOM90.PBD was included. By mistake , I opened the same workspace in PB10.0 and the application was migrated completed. Later coming back to PB9.0 and opening the same workspace , found that , in the system tree PDB files has zero object, It is not showing anything and the appl...

Datawindow error in powerbuilder 10
I have migrated my application from Powerbuilder 6.5 to 10. Randomly I am getting a error while retrieving a datawindow which is as follow: Datawindow control : ppo_uds_super Data Object : d_mnt_sys_parm Row : 0 Buffer : Primary DB Error Code : 207 Sql Error Text : Select error: SQLSTATE = S0022 [Microsoft][ODBC SQL Server Driver][SQL Server]Invalid column name 'YN'. In the above mentioned datawindow's select statement, there is no such column. Please advice to overcome this problem. ---== Posted via the PFCGuide Web Newsreader ==--- http://www.pfcguide.com/_news...

Web resources about - powerbuilder 10 build 8075 datawindow dddw bug. - sybase.powerbuilder.general

PowerBuilder - Wikipedia, the free encyclopedia
PowerBuilder is an integrated development environment owned by Sybase , a division of SAP . It has been in use since 1991, peaking around 1998 ...

Sybase PowerBuilder tool readied for Microsoft's .Net
... Win32 or newer style .Net development After several years of work, Sybase is ready to deliver on the final step in its plan to move PowerBuilder ...

Jim O'Neil (@jimoneil) on Twitter
Sign in Sign up To bring you Twitter, we and our partners use cookies on our and other websites. Cookies help personalize Twitter content, tailor ...

Open Directory - Computers: Programming: Languages
about dmoz - dmoz blog - report abuse/spam - help the entire directory only in Programming/Languages Description Top : Computers : Programming ...

The HP Booth Staff (Goons) Owe Me an Apology
... when you might need to use it. For instance, when I was in the WinRunner world there were plugins for driving terminal emulators and powerbuilder ...

Contact Us - Sybase Inc
Thanks for visiting the 主页 section of Sybase.com. Here you will find information about Contact Us. For more information about Business Intelligence, ...

热门搜索 - 我的异常网
... 我的异常网 » 热门搜索 sdpnet2 移动【A111】其它用户原因鉴权失败,是什么意思啊 http:// 192.168.1.102:22578 本网站服务器位于美国,受美国法律保护 MiniUI js 破解 http://192.168.1.103:8080/ powerbuilder ...

Mobile app security: Always keep the back door locked
The best way to keep mobile apps safe is to secure the services they connect to.

10 Tech Skills That Will Instantly Net You A $100,000+ Salary
... that let's developers run Java applications. Java is highly popular language for writing web apps and custom enterprise apps. No. 8: PowerBuilder ...

Top Ranked Articles
Top Ranked Articles - Free source code and tutorials for Software developers and Architects.; Updated: 23 Feb 2013

Resources last updated: 12/26/2015 11:32:56 PM